Lab & Field Conductivity Sensors

Conductivity / TDS Sensors for Laboratory & Field Use

k=0.1 Laboratory Conductivity Sensor

Description Glass body k=0.1 Conductivity sensor for low Conductivity applications. Precision platinised platinum plates. Plates are mounted inside a 12mm tube, making the sensor immune to the effects of vessel size on readings. Submersible to 1 metre.
Range 0.1 uS/cm to 2000 uS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 120 x 12 mm
Ordering
Description Part No
Current Meter Models  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors)  122229
Sensor with 1m cable to suit labCHEM & smartCHEM Series (inbuilt ATC + Temp sensors)  122232
Extra cable (order by the metre) 130040
Obsolete Meter Models  
Sensor with 1m cable to suit 2102A and 900-C (no ATC sensor) 122204
Sensor with 1m cable to suit 900-C (inbuilt ATC sensor) 122225
Sensor with 1m cable to suit 2100, LC & 901 Series (inbuilt ATC sensor)  122224

k=1.0 Laboratory Conductivity Sensor

Description Glass body k=1.0 Conductivity sensor for general purpose Conductivity applications. Precision platinised platinum plates. Plates are mounted inside a 12mm tube, making the sensor immune to the effects of vessel size on readings. Submersible to 1 metre.
Range 1 uS/cm to 20 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 120 x 12 mm
Ordering
Description Part No
Current Meter Models  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors)  122216
Sensor with 1m cable to suit labCHEM & smartCHEM Series (inbuilt ATC + Temp sensors) 122230
Extra cable (order by the metre) 130040
Obsolete Meter Models  
Sensor with 1m cable to suit 2102A and 900-C (no ATC sensor) 122206
Sensor with 1m cable to suit 900-C (inbuilt ATC sensor) 122227
Sensor with 1m cable to suit 2100, LC & 901 Series (inbuilt ATC sensor)  122226

k=1.0 Laboratory Conductivity Sensor, Low Volume 10mm immersion

Description Glass body k=1.0 Conductivity sensor for general purpose Conductivity applications. Precision platinised platinum plates. Plates are mounted inside a 12mm tube, making the sensor immune to the effects of vessel size on readings. Submersible to 1 metre.

This version is made for a minimum immersion depth of 10mm, making it suitable for small sample volumes such as soil extracts.

Range 1 uS/cm to 20 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 120 x 12 mm
Ordering
Description Part No
Sensor with 1m cable to suit WP, Aqua & MC Series, for 10mm minimum immersion (inbuilt ATC + Temp sensors)  122214
Extra cable (order by the metre) 130040

k=10 Laboratory Conductivity Sensor

Description Glass body k=10 Conductivity sensor for high level Conductivity applications. Precision platinised platinum plates. Plates are mounted inside a 12mm tube, making the sensor immune to the effects of vessel size on readings. Submersible to 1 metre.
Range 10 uS/cm to 200 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 120 x 12 mm
Ordering
Description Part No
Current Meter Models  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors)  122212
Sensor with 1m cable to suit labCHEM & smartCHEM Series (inbuilt ATC + Temp sensors)  122234
Extra cable (order by the metre) 130040
Obsolete Meter Models  
Sensor with 1m cable to suit 2102A and 900-C (no ATC sensor) 122202
Sensor with 1m cable to suit 900-C (inbuilt ATC sensor) 122223
Sensor with 1m cable to suit 2100, LC & 901 Series (inbuilt ATC sensor)  122222

k=0.1 Field Conductivity Sensor

Description Plastic body k=0.1 Conductivity sensor for low Conductivity applications. Precision platinised platinum wire electrodes.  Submersible to  50 metres.
Range 0.1 uS/cm to 2000 uS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 110 x 12 mm (diameter at sensing area).
Ordering
Description Part No
AQUA & WP Meters  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122235
Sensor with 3m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122238
Sensor with 5m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122199
Extra cable (order by the metre) 130040
90 Meters  
Sensor with 1m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122195
Sensor with 5m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122197
Extra cable (order by the metre) 130040

k=1.0 Field Conductivity Sensor

Description Plastic body k=1.0 Conductivity sensor for general purpose Conductivity applications. Precision platinised platinum wire electrodes.  Submersible to  50 metres.
Range 1 uS/cm to 20 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF). Can be used to 90 OC (194 OF) if specified with nylon cover at ordering.
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 110 x 22 mm
Ordering
Description Part No
AQUA & WP Meters  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122201
Sensor with 3m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122236
Sensor with 5m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122198
Extra cable (order by the metre) 130040
90 Meters  
Sensor with 1m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122193
Sensor with 5m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122196
Extra cable (order by the metre) 130040

k=10 Field Conductivity Sensor 

Description Plastic body k=10 Conductivity sensor for high level Conductivity applications. Precision platinised platinum plates.  Submersible to  50 metres.
Range 10 uS/cm to 200 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF).
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument to which the sensor is connected.
Dimensions 110 x 22 mm
Ordering
Description Part No
AQUA & WP Meters  
Sensor with 1m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122221
Sensor with 3m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122237
Sensor with 5m cable to suit WP, Aqua & MC Series (inbuilt ATC + Temp sensors) 122219
Extra cable (order by the metre) 130040
90 Meters  
Sensor with 1m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122194
Sensor with 5m cable to suit 90 Series (inbuilt ATC + Temp sensors) 122218
Extra cable (order by the metre) 130040

HK-1 Conductivity Sensor for HP81 & HP81T

Description Plastic body Conductivity sensor designed specifically for Hydroponics applications.
Range 10 uS/cm to 10 mS/cm. 
Temperature Range 0 to 60 OC (32 to 140 OF).
Sensing Electrode Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the HP81 and HP81T
Dimensions 110 x 22 mm
Ordering
Description Part No
Sensor with 1m cable to suit HP81 & HP81T (inbuilt ATC sensor) 122208
Extra cable (order by the metre) 130040

k=10 Pipette Style Sensor for Naturopaths

Description Plastic body pipette style Conductivity sensor designed specifically for low volume Naturopathic applications. Can measure less than 0.5 mL.
NOTE: Although this is a k=10 sensor, its use for general purpose applications is not recommended. The small size of the plates provides linearity over a small range only.
Range 2 mS/cm to 20 mS/cm. 
Temperature Range 0 to 60 OC (32 to 140 OF).
Sensing Electrode Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided to suit the instrument for which it is supplied.
Dimensions 110 x 22 mm
Ordering
Description Part No
Sensor with 1m cable to suit 2100, LC and 901 Series (inbuilt ATC sensor) 122210
Extra cable (order by the metre) 130040

 

Download this Specification Sheet in PDF format (0.31MB, .PDF)

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.
If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.