Industrial Conductivity Sensors

Conductivity / TDS Sensors for Process Controllers & Transmitters

k=0.1 GK Series Conductivity Sensor

Description k=0.1 Conductivity sensor for low conductivity applications. Made from chemical resistant RYTON plastic. 3/4" BSP thread at front, 1/2" BSP thread at rear. Precision platinised platinum wire electrodes. Inbuilt sensor for automatic temperature compensation. Supplied with 5m cable. Pressure rated to 5 bar.
Range 0.1 uS/cm to 2000 uS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 90 OC (32 to 194 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided.
Dimensions 130 x 12 mm (diameter at sensing area).
Ordering
Description Part No
Sensor with 5m cable to suit TPS Conductivity and TDS controllers 112205
Extra cable (order by the metre) 130040

k=1.0 GK Series Conductivity Sensor

Description k=1.0 Conductivity sensor for general purpose Conductivity applications. Made from chemical resistant RYTON plastic. 3/4" BSP thread at front, 1/2" BSP thread at rear. Precision platinised platinum wire electrodes. Inbuilt sensor for automatic temperature compensation. Supplied with 5m cable. Pressure rated to 5 bar.
Range 1 uS/cm to 20 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF). Can be used to 90 OC (194 OF) if specified with nylon cover at ordering.
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided.
Dimensions 130 x 22 mm (diameter of PVC cover).
Ordering
Description Part No
Sensor with 5m cable to suit TPS Conductivity and TDS controllers 112206
Extra cable (order by the metre) 130040

k=10 GK Series Conductivity Sensor

Description k=10 Conductivity sensor for high level Conductivity applications. Made from chemical resistant RYTON plastic. 3/4" BSP thread at front, 1/2" BSP thread at rear. Precision platinised platinum electrodes. Inbuilt sensor for automatic temperature compensation. Supplied with 5m cable. Pressure rated to 5 bar.
Range 10 uS/cm to 200 mS/cm. Can be used for higher measurements, but errors due to non-linearity may occur.
Temperature Range 0 to 60 OC (32 to 140 OF)
Sensing Electrodes Platinised platinum.
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided.
Dimensions 130 x 22 mm (diameter of PVC cover).
Ordering
Description Part No
Sensor with 5m cable to suit TPS Conductivity and TDS controllers 112207
Extra cable (order by the metre) 130040

4 Terminal Conductivity Sensor for Hydroponics Controllers

Description Plastic bodied Conductivity sensor using 4 terminal design to reduce effects of fouling on Conductivity readings. 

These sensors are compatible only with the hydroCHEM Series of Hydroponics controllers.

Range 0.1 mS/cm to 20 mS/cm. 
Temperature Range 0 to 60 OC (32 to 140 OF).
Sensing Electrodes 4 Platinum wires
Temperature Compensation Inbuilt sensor for Automatic Temperature Compensation (ATC) provided.
Dimensions 110 x 22 mm
Ordering
Description Part No
Sensor with 1m cable to suit hydroCHEM-DS Dosing System (with 3x dosing pumps) 122205
Sensor with 5m cable to suit hydroCHEM controller (no dosing pumps) 122215
Extra cable (order by the metre) 130040