90-FLT

Field-lab Analysers for Ph, Mv, Conductivity, Tds, Salinity, Dissolved Oxygen, Turbidity & Temperature

90-FLT

 

 

The TPS range of Field Lab Analysers provide a complete measurement solution for several of the most important water quality parameters.

User-friendly
All measurements are shown simultaneously on the 80 character display. There is no need to change modes to check any of your vital data. The user-friendly menu system guides the operator through all operations such as calibration, setup etc. Full text help and error messages are provided along the way.

Waterproof
The 90 series is designed for rugged field applications in wet environments. The case, keypad and connectors are rated to IP65.

Good Laboratory Practices
To comply with GLP guidelines, the date, time and results of the last calibration are stored in memory, along with the unit's serial number. This data can be displayed or sent directly to the RS232 port. Warning of failed calibration is provided. All readings stored in memory are stamped with the date and time. 

Notepad Function
A standard feature of the 90 series is the Notepad function. Up to 8100 sets of readings (depending on model) can be recorded for later review. These can be downloaded to a printer or computer via the RS232 port. For added functionality, the user is able to enter up to two additional items to be tagged on to the reading. Many operators use this function as a pond or site identifier, depth or readings from other instruments.

Datalogging
Automatic datalogging provides the capability to automatically record up to 8100 sets of readings (depending on model) at user-set intervals. The unit remains dormant between readings and only wakes up whenever a reading is due. Battery life is considerably improved with this facility.

RS232 Serial Port Interface
All recorded data can be downloaded directly to a Printer or Computer with the standard RS232 port (cable sold separately). With the WinTPS communication software, many instrument functions can be controlled from the computer. This makes the units ideal for remote monitoring.

The 90 Series is proudly designed and manufactured in Australia. Our aim is to provide you with the best quality, service and value for money. The TPS Quality System has been certified in accordance with the AS/NZS ISO 9001 standard. Since 1968, TPS has built a reputation for excellent backup service that is second to none.

Product price

Product ID Product options Price
116524 90FLT Waterproof pH-mV-Cond-TDS-DO2-Turbidity-Temp Logger $2,432.00
126105/1 90FLT with 1 metre pH, ORP, DO2, Turb, k=0.1, k=1 or k=10 Cond sensor - specify $4,963.00
126105/5 90FLT with 5 metre pH, ORP, DO2, Turb, k=0.1, k=1 or k=10 Cond sensors - specify $5,170.00

Specifications

pH
Range : 0.00 to 14.00 pH
Resolution : 0.01 pH
Accuracy : В±0.01pH
Impedance : >3 x 1012 Ohms
Asymmetry : -1.00 to +1.00 pH
Range : 85 to 105%

Temperature
Compensation : Automatic, -5 to 100oC
Calibration : 2 Point automatic
pH Buffers : Auto recognition of pH4.01, pH6.86, pH7.00,
pH9.18 and pH10.01.
Other buffers can be keyed in at calibration.

ORP (90FL-T & 90FL-MV only)
Range : 0 to +/-1999 mV
Resolution : 1 mV
Accuracy : +/-1 mV

Conductivity
Ranges : 4 ranges with auto range selection
k=0.1 Sensor : 
0 to 2.000 uS/cm
0 to 20.00 uS/cm
0 to 200.0 uS/cm
0 to 2000 uS/cm

k=1 Sensor : 
0 to 20.00 uS/cm
0 to 200.0 uS/cm
0 to 2000 uS/cm
0 to 20.00 mS/cm

k=10 Sensor : 
0 to 200.0 uS/cm
0 to 2000 uS/cm
0 to 20.00 mS/cm
0 to 200.0 mS/cm

Resolution : 0.05% of full scale of selected range.
Accuracy : В±0.5% of full scale of selected range at 25oC.
Temperature
Compensation : All readings automatically normalised to 25oC at -2.2%/oC.
Zero 
Calibration : Automatic in air. 

Calibration : Automatic to user- defined standard. 

TDS
Ranges : 4 ranges with auto range selection.
k=0.1 Sensor : 
0 to 1.000 ppM
0 to 10.00 ppM
0 to 100.0 ppM
0 to 1000 ppM

k=1 Sensor : 
0 to 10.00 ppM
0 to 100.0 ppM
0 to 1000 ppM
0 to 10.00 ppK

k=10 Sensor : 
0 to 100.0 ppM
0 to 1000 ppM
0 to 10.00 ppK
0 to 100.0 ppK

Resolution : 0.1% of full scale of selected range.
Accuracy : В±0.5% of full scale of selected range at 25oC.
Temperature
Compensation : All readings automatically normalised to 25oC at -2.2%/oC.
Zero 
Calibration : Automatic in air.
Calibration : Automatic to user- defined Conductivity standard.

Salinity
Ranges :
k=0.1 Sensor : 0 to 0.10 % 0 to 1.0 PSU
k=1 Sensor : 0 to 1.19 % 0 to 11.9 PSU
k=10 Sensor : 0 to 8.00 % 0 to 80.0 PSU

Resolution : 0.01 % or 0.1 PSU
Accuracy : В±0.5% of full scale of selected range at 25oC.

Temperature
Compensation : All readings automatically normalised to 25oC at -2.2%/oC.

Zero Calibration : Automatic in air.
Calibration : Automatic to user- defined Conductivity standard.

Dissolved Oxygen
Ranges :
0 to 32.00 ppM (mg/L)
0 to 320.0 %Saturation
0 to 66.0 %Gaseous
Resolution : 
0.01 ppM (mg/L)
0.1 %Saturation
0.1 %Gaseous

Accuracy :
В±0.02 ppM (mg/L)
В±0.3 %Saturation
В±0.1 %Gaseous

Temperature
Compensation : Automatic for solubility (ppM only) and membrane permeability.
Zero
Calibration : Automatic at less than 5%.
Calibration : Automatic in air.

Turbidity (90FL-T only)
Ranges : 
0.1 to 200.0 NTU
0 to 2000 NTU
(Ranges subject to sensor performance)
Resolution : 
0.1 NTU
1 NTU
Accuracy : +/-1 NTU
Linearity : 3%

Temperature
Coefficient : -0.3%/oC, 0 to 40oC
Zero
Calibration : Automatic in distilled water.
Calibration : Automatic to user- defined standard.

Temperature
Range : -10.0 to 110.0 oC (Cond. sensor limit 60 oC)
Resolution : 0.1 oC
Accuracy : +/-0.2 oC
Calibration : Automatic, 1 or 2 point

Good Laboratory Practices
Date, time and value of last calibration for each parameter are stored. This information can be recalled or sent to the RS232 port at any time.

Warning of failed calibration is provided.
All readings stored in memory are stamped with the date and time.

Datalogging
Memory Capacity
90FL : 8100 readings (6500 with extra data input active).
90FL-MV : 7200 readings (5900 with extra data input active).
90FL-T : 6500 readings (5400 with extra data input active).

Extra Data Input 2 extra items of data can be input when using the Notepad function. Each item can be a maximum of 4 characters, including a decimal point. Extra Data items are labelled A and B.

Automatic Logging
All 3 models can be programmed to...
- Automatically log from 1 to 288 readings per day.
- Automatically log readings at a preset interval for a preset duration.

RS232 Serial Port Output
8 Bits, No Parity, 1 Stop Bit, XON/OFF Protocol.
300, 9600 & 19200 baud available.

Display 2 line x 40 Character alphanumeric LCD shows all readings simultaneously. 

Keypad 5 Function keys, Menu key, 14 data entry keys, OFF, ON. 

Dimensions 230 x 140 x 100 mm

Mass
Meter only : Approx 1.5 kg
Full Kit : Approx 6.5 kg

Environment
Temperature : 0 to 45 oC
Humidity : 0 to 90% R.H.

Power
7.2V Rechargeable NiCad Battery
Any 12VDC supply will recharge the battery.

Ordering Information

90FL 
Part No
5 metre bundle 126103/5:
90-FL including 5m cables & sensors............126103/5

5 metre Option Includes
Submersible pH, sensor, 5m cable...............111224
k=1 Conductivity/Temperature Sensor, 5m........122196
YSI 5739 Dissolved Oxygen Sensor (no cable)....123204
5m cable for sensor............................123219
pH7.00 Buffer, 200mL...........................121387
pH4.01 Buffer, 200mL...........................121381
2.76mS/cm Conductivity Standard, 200mL.........122306
Battery Charger................................130009
Manual.........................................130050

90FL-MV 
Part No
5 metre bundle 130018/5:
90-FLMV including 5m cables & sensors..........130018/5

5 metre Option Includes
Submersible pH, sensor, 5m cable...............111224
ORP, Submersible, 5m...........................111259
k=1 Conductivity/Temperature Sensor, 5m........122196
YSI 5739 Dissolved Oxygen Sensor (no cable)....123204
5m cable for sensor............................123219
pH7.00 Buffer, 200mL...........................121387
pH4.01 Buffer, 200mL...........................121381
2.76mS/cm Conductivity Standard, 200mL.........122306
ORP Calibration Solution, 200mL................121309
Battery Charger................................130009
Manual.........................................130050

90FL-T 
Part No
5 metre bundle 126105/5:
90-FLT including 5m cables & sensors...........126105/5

5 metre Option Includes
Submersible pH, sensor, 5m cable...............111224
ORP, Submersible, 5m...........................111259
k=1 Conductivity/Temperature Sensor, 5m........122196
YSI 5739 Dissolved Oxygen Sensor (no cable)....123204
5m cable for dissolved oxygen sensor...........123219
Turbidity Sensor, no cable.....................125186
5m cable for turbidity sensor..................125187
pH7.00 Buffer, 200mL...........................121387
pH4.01 Buffer, 200mL...........................121381
2.76mS/cm Conductivity Standard, 200mL.........122306
ORP Calibration Solution, 200mL................121309
90 NTU Diluted Standard, 200 mL................125216
900 NTU Diluted Standard, 200mL................125220
Black calibration Bottle x 2...................125300
Battery Charger................................130009
Manual.........................................130050

Same Price Interchange Option:
Choose between k=0.1, k=1 and k=10 Conductivity Sensor
k=10 Conductivity/Temperature Sensor, 5m.......122218
K=0.1 Conductivity/Temperature Sensor, 5m......122197

Options and Accessories
pH Sensor Upgrade: difficult samples such as meat, dairy, slurries...
pH, Intermediate Junc, 5m......................121200/5

ORP Sensor Upgrade: difficult samples such as meat, dairy, slurries...
ORP, Intermediate Junc, 5m.....................121260/5

BOD Dissolved Oxygen Sensors:
YSI non-stirring BOD Sensor (1.5m cable).......123214
YSI self-stirring BOD Sensor (1.5m cable)......123213

Dissolved Oxygen Sensor Maintenance:
YSI5739 Field Sensor & Non Stirring BOD Sensor
Membrane & filling solution kit................123300
Filling Solution only, 45mL....................123303
Zero calibration Sodium Sulphite...............123302
Rejuvenation kit...............................123037
Diaphragm replacement kit......................123304
(Above for YSI5739 Field Sensor Only)

YSI Self-Stirring BOD Sensor
Membrane Cap Kit...............................123308

Temperature Sensor:
Temperature Sensor, 5m cable...................124210

Turbidity Sensor Protector:
Sensor Protector Cover.........................125189

Sensor Holders:
Sensor holder for 90FL & 90FL-MV, 5m cable.....121343
Sensor holder for 90FL-T, 5m cable.............121345

Cable Extension:
Extra cable, per metre.........................130040

Computer Interface:
RS232 serial port cable to connect to computer.130015
Serial to USB adaptor cable (used with 130015).130087
WinTPS Software for Windows....................130086

Power options:
12V Solar charging panel.......................130012
12V Car cigarette lighter lead.................130013
Clip lead for external 12V battery.............130024

Carry case:
Waterproof carry case..........................130058

Download this Specification Sheet in PDF format (0.31MB, .PDF)
Download the manual for this 90-FL (0.64MB, .PDF)
Download the manual for 90-FLMV (0.71MB, .PDF)
Download the manual for 90-FLT (0.88MB, .PDF)

Hint : Right click on a link, then select "Save Target As..." or "Save Link As..." to save the file to your own computer.
If you do not have Adobe Acrobat in your computer, a free Acrobat Reader can be downloaded by clicking on the following link.